High Conversion Efficiency
High panel efficiency to guarantee high power output
Self-Cleaning And Anti-Reflection Glass
Coating glass for self-cleaning reduces surface dust
Outstanding Low Irradiation Glass
Outstanding panel performance even in weak light conditions
Excellent Durability
Wind load up to 2400 Pa, Snow load up to 5400 Pa
0~+5W Positive Power Tolerance
Easy Installation
Model Type | TT395 108PM10 | TT400 108PM10 | TT405 108PM10 | TT410 108PM10 |
Peak Power (Pmax) | 395 Wp | 400 Wp | 405 Wp | 410 Wp |
Module Efficiency | 20.23 | 20.48 | 20.74 | 21.00 |
Maximum Power Voltage (Vmp) | 30.90 | 31.10 | 31.30 | 31.50 |
Maximum Power Current (Imp) | 12.79 | 12.86 | 12.94 | 13.02 |
Open Circuit Voltage (Voc) | 36.90 | 37.10 | 37.40 | 37.60 |
Short Circuit Current (Isc) | 13.62 | 13.70 | 13.77 | 13.85 |
Power Tolerance | 0~+5W | |||
Maximum System Voltage | 1500V DC | |||
Operating Temperature | -40 ~ +85°C | |||
Fire Safety Class | C | |||
Maximum Series Fuse Rating | 25A |
MECHANICAL SPECIFICATIONS
Cell Dimensions(mm) | 182x91 |
Cells per Module(pcs) | 108 (6x18) |
Weight(kg) | 22.0 |
Panel Dimensions(mm) | 1722x1134x35 |
Max. Wind/Snow Load(Pa) | 2400/5400 |
Junction Box | IP68 |
Junction Box Cable Length(mm) | 350-1600 |
TEMPERATURE CHARACTERISTICS
Temp. Coeff. of (Isc) | 0.05%/°C |
Temp. Coeff. of (Voc) | -0.27%/°C |
Temp. Coeff. of (Pmax) | -0.35%/°C |
PACKING CONFIGURATION
Container | 40' GP |
Pieces per Pallet | 31 |
Pieces per Container | 806 |
Pallet Per Container | 26 |
PHYSIKALISCHE EIGENSCHAFTEN
ELECTRICAL CHARACTERISTICS
*Note 1: The specifications are obtained under the standard test conditions: 1000W/m2 solar irradiance, 1.5 Air Mass and cell temperature of 25°C. Measurement uncertainty for all panels is 6%. The actual transactions will be subject to the contracts. These parameters are for reference only and it is not a part of the contracts. The specifications are subject to change without prior notice.
*Note 2: For roof, facades and installations on similar surfaces, solar panels should be mounted over a fire-resistant covering suitable for this application, with adequate ventilation between the back of the solar panels and the mounting surface. Improper installations are hazardous and may spark a fire. Solar panels must not be mounted on structures and roofs which are made of not fire-resistant materials such as plastic layer, transparent plastic or similar materials without any fire-protection layer. Usage and installation not in accordance with the guidelines as outlined in the installation manual will terminate the warranty. Please refer to the installation manual and the warranty documents for further details.